Cystatin C concentration during the first three postnatal days in healthy term newborns

V Mikulic, D Rogic, I Mikulic, MJ Raguz… - … für Geburtshilfe und …, 2022 - thieme-connect.com
… Cys-C was measured within first three days of birth using particle-enhanced turbidimetric
immunoassay (PETIA) on the Architect plus ci8200 analyzer. …

Analytical performances of PENIA and PETIA urinary cystatin C determination allow tubular injury investigation

AS Bargnoux, V Azoury, S Badiou… - Annals of Clinical …, 2019 - journals.sagepub.com
… CysC in urine was measured by a particle-enhanced nephelometric immunoassay using
Siemens reagents and by a particle-enhanced turbidimetric immunoassay using DiaSys …

[HTML][HTML] Cystatin C serum levels in healthy children are related to age, gender, and pubertal stage

N Ziegelasch, M Vogel, E Müller, N Tremel… - Pediatric …, 2019 - Springer
measured using the rapid and precise particle enhanced turbidimetric or nephelometric
immunoassays (… using the turbidimetric immunoassay (PETIA) Tina-quant® Cystatin C (Roche …

The validation of immunoblot SDS-PAGE as a qualitative and quantitative method for the determination of urinary Cystatin C in neonates

C Grasselli, A Barbati, L Cesarini, R Pellegrino… - Clinical …, 2021 - Elsevier
urinary cyst-C are: particleenhanced turbidimetric immunoassay (PETIA), particle
enhanced … This study aims to examine an assay for measuring urinary cystatin C to potentially …

[HTML][HTML] Detection of urinary cystatin-c in IUGR neonates by immunoblot SDS-PAGE

C Grasselli - Pediatrics & Neonatology, 2022 - Elsevier
… Furthermore, this study demonstrates urinary levels of cyst-C, measured by EIA, were inversely
correlated with renal volumes, gestational age and birth weight. The same samples have …

Effects of CST3 Gene G73A polymorphism on cystatin C in a prospective multiethnic cohort study

NA Mohd Tahir, S Mohd Saffian, FH Islahudin… - Nephron, 2020 - karger.com
… serum cystatin C and creatinine levels by particle-enhanced … function measurement. Kidney
Int. 2004 Apr; 65(4):1416–21. … Evaluation of Gentian cystatin C reagent on Abbott Ci8200

Association of different estimates of renal function with cardiovascular mortality and bleeding in atrial fibrillation

Z Hijazi, CB Granger, SH Hohnloser… - Journal of the …, 2020 - Am Heart Assoc
… Among the eGFR equations, those based on cystatin C yielded the highest C … the Architect
system ci8200 (Abbott Laboratories) using the particleenhanced turbidimetric immunoassay

Circulating heart failure biomarkers beyond natriuretic peptides: review from the Biomarker Study Group of the Heart Failure Association (HFA), European Society of …

…, AM Richards, P Seferovic, C Mueller… - European journal of …, 2021 - Wiley Online Library
… assays are developed to measure cystatin C both as an in vitro … Cystatin C immunoassay is
a particle-enhanced turbidimetric … , ARCHITECT, AU, VITROS, BS and Cobas on the Architect

Strong associations between early tubular damage and urinary cytokine, chemokine, and growth factor levels in elderly males and females

B Fellström, J Helmersson-Karlqvist, L Lind… - Journal of Interferon & …, 2021 - liebertpub.com
… for urinary creatinine measured with an isotope dilution mass spectrometry calibrated modified
kinetic Jaffe reaction on an Architect Ci8200 … had urine cystatin C values above this limit. …

Estimation and measurement of glomerular filtration rate in children

CL Salvador - 2020 - duo.uio.no
… There are several different methods for measuring cystatin C, and the most common is particle